Furuno FR-1760DS Marine RADAR User Manual


 
5-15
6. Close the cover.
7. Referring to the Operator’s Manual, conduct the self test. Confirm program number. If
the program number is younger than the number recorded on the floppy disk (sup-
plied), the program should be updated. If updating is not required, go to step 19.
8. Loosen the two screws at the front of the display unit and raise the front panel.
Screw
Figure 5-16 Display unit, front view
9. Dismount the panel on the underside of the control section.
Connector (J304) added
with program update
MAIN PANEL
Board (03P9247)
Stay
Figure 5-17 Display unit, front panel raised