Graco 249057 Marine Sanitation System User Manual


 
13310643
Service
Fig. 19. Grease o-ring (221) and place on sleeve. Slide
sleeve/piston rod assembly into bottom of cylinder . Re-
place o-ring (207) if desired.
Note: O-ring (207) is not required for safe pump opera-
tion.
Fig. 19
207
221
ti4258a
Fig. 21. Torque seal and packing nut (202) down onto
throat adjustment spacer (228) to 100 +/--10 in-lb.
Remove throat adjustment spacer (228) when pump
packings begin to leak after much use. Then tighten
packing nut down until leakage stops or lessens. This
allows approximately 100 gallons of additional opera-
tion before a repacking is required.
Fig. 20
202
7726b
228
Fig. 21. Push up retaining spring (26) with screwdriver .
Fig. 21
26
ti4258a
Fig. 22. Push in pin (29).
Fig. 22
Note: Make sure retaining ring f alls into slot.
29
26
ti4258a