Hitachi SJ700 Marine Battery User Manual


 
Ease of maintenance Easy operation
Field replacement of cooling fan (s) and DC bus capacitors
can be accomplished in a fraction of the time.
Using Logic terminal move to SJ700D/SJ700 without wiring
change.
Read SJ300 Parameter by WOP remote operator and write
them in to SJ700D/SJ700
Displays only parameters changed from factory default
The Modbus-RTU communication is embedded as standard
along with a dedicated terminal.
Other fieldbus communications such DeviceNet and
PROFIBUS-DP are supported with optional fieldbus modules.
-DeviceNet is a trade mark of Open DeviceNet Vender Association, Inc.
-PROFIBUS-DP is a registered trade mark of PROFIBUS Nutzer
Organization
Long lifetime components &
Lifetime warning function
Long lifetime components
Design lifetime 10 Years or more for DC bus capacitors & Cooling
Fan.Cooling Fan ON/OFF control function for longer fan life.
*Condition for lifetime calculation -
Ambient temperature: 40 deg C (SJ700B: 30 deg C)
Ambient condition: No corrosive gas, oil mist nor dust
10 years is a design lifetime base on calculation, and not guaranteed
Lifetime warning function
Lifetime warning function helps to perform preventive
maintenance before a failure occurrence.
DC bus capacitor, cooling fan, heat sink temperature and
motor temperature can be monitored in order to replace
components prior to failure.
Easy-removable
DC bus Capacitors
(SJ700D/SJ700: above 15kW
SJ700B: above 18.5kW)
Easy-removable
Cooling Fan
SJ300series SJ700series
Network compatibility
Parameter
read write
Removable Control circuit terminals
(Move to SJ700D/SJ700 without rewiring)
Data comparison display mode
Direct digit edit mode for quicker selection of parameter.
Returning to output frequency monitor display (d001) by
holding the FUNC key for 3 seconds regardless of the
current content.
Other functions
Displays only pre-defined basic parameters which are used
commonly
Basic parameter display mode
Displays only user defined parameters
(up to 12 parameters, U001 to U012)
User-define parameter display mode
Basic
mode
Chose Basic
Parameter
Indication only
Basic Parameter
Easy-removable construction
for maintenance
User selection of displayed
parameters
Simple & Low cost wiring, ease of installation
and replacement using feildbus commuincation
*1 Control circuit terminals comparison table
Series Input terminals
SJ700D/SJ700
SJ700B
SJ300
L300P
Output terminals
5 terminals
(Open collector outputs)
2 terminals
(Relay outputs)
9 terminals
(Intelligent 8terminals,FW)
6 terminals
(Intelligent 5terminals,FW)
5