Hoshizaki ROX-20TB2-U Marine Sanitation System User Manual


 
21
5. FUNCTIONS AND OPERATION
[a] NORMAL MODE
The following menus are available in the normal mode. The display shows from 1 to 3
every time the display select button is pressed.
No. Menu Description
1 Cell run time (h) Total electrolytic cell run time at present.
2 Current (A)
Current owing in electrolytic cell at present as measured by
current sensor.
3 Voltage (V)
Voltage provided on electrolytic cell at present as measured
by main control board.
[b] SHORT MODE
Use this mode to change the polarity every 2 minutes.
1) While the power switch (ground fault interrupter) is off, hold down the ush button and
set/reset button.
2) Turn on the power switch (ground fault interrupter).
3) After 5 seconds, release the ush button and set/reset button.
Note: The operation lamp ashes while the short mode is selected.
[c] ADJUSTMENT MODE
The following menus are available in the adjustment mode.
No. Menu Factory default Adjustable range/increments
A1 Current (A) Lo: 10, Std: 10, Hi: 10
5.0 to 18.0/0.1
[wt=77°F(25°C)]
A2 Voltage (V) Lo: 12, Std: 12, Hi: 12 7.0 to 18.0/0.1
A3 Total ow rate (L/min) Lo: 3.0, Std: 4.0, Hi: 6.0 1.5 to 8.0/0.1
A4 Combination 1 Main: 1, Sub: 2
A5 Portion control time (min) 1 1 to 60/1
A6
Cleaning water dispensing
time for hand washing (s)
30 15 to 120/5
A7
Sanitizing water dispensing
time for hand washing (s)
30 15 to 120/5
A8
Cell run time/reversal time
reset
N/A
Display present run time, then
hold down set/reset button
(10s) to reset
A9 Initial ash time (s) Std Std, 0 to 20/1