Hoshizaki ROX-20TB2-U Marine Sanitation System User Manual


 
22
No. Menu Factory default Adjustable range/increments
A10 Cell replacement time (h) 3000 1500 to 9000/100
A11 Cell reversal time (h) 12 0.033 (check), 1 to 150/1
A12
Continuous dispensing
protection time (min)
Cont Cont, 10 to 720/10
A13 Single nozzle 2 Single: 1, Std: 2
A14
Water temperature correction
factor
4 0 to 8/1
A15
Flow rate adjustment factor,
operation time factor
0.3 0.1 to 2.0/0.1
A16 Skip N/A Skip
A17
Flow rate correction value (L/
min)
0 -0.5 to 0.5/0.1
A18
Water softener regeneration
output cycle (h)
0 0 to 100/1
A19
Salt water supply factor,
feedback
1.0 1.0 to 5.0/0.1
A22
Salt water supply factor, initial
non-electrolysis time (s)
5 1 to 10/1
A23
Salt water supply factor,
feedback cycle
1.0 1.0 to 5.0/0.1
A25
Salt water supply factor,
stroke subtraction after
reaching set point (times/s)
N/A Skip
A26 Reset N/A
Display "rSEt", then hold down
set/reset button (10s) to reset
A27
Flow control valve open/
closed
N/A Display current status
* Basically do NOT adjust the menus in gray.
[d] CHECK MODE
The following menus are available in the check mode.
No. Menu
C1 Inputs
C2 Inputs
C3 Outputs
C4 Salt water pump stroke (spm: strokes per minute)
C5 Total ow rate (L/min)
C6 Water temperature (°C)
C7 Set current at present water temperature (A)
C8 Corrected current (A)
C9 Elapsed cell reversal time (min)