4. REMOVAL AND REPLACEMENT OF COMPONENTS
[a] ELECTROLYTIC CELL
WARNING
To prevent electric shock, be careful not to crush or drag the pipes or wires
when removing the electrolytic cell.
NOTICE
To prevent water leaks resulting in wetting the surrounding properties, be sure to
drain water before removing the electrolytic cell.
1) Remove the front panel, turn off the power switch (ground fault interrupter), and unplug
the unit.
2) Close the water supply line shut-off valve, and disconnect the water supply, cleaning
water, and sanitizing water hoses.
3) Unscrew and remove the top and side panels.
4) Remove the drain cap on the back of the unit to drain the electrolytic cell.
5) Disconnect the power cord (red/black) on the electrolytic cell from the terminal block.
6) Remove the four union nuts from the electrolytic cell.
7) Unscrew the cell stopper and frame assembly, and remove the cell stopper from the unit
base.
8) Slide out the electrolytic cell towards you.
9) To replace, reverse the above pocedure.