Nortel Networks P0992639 01 SONAR User Manual


 
102
/ Troubleshooting
Modular ICS Companion Installer Guide P0992639 01
Alarm codes
For a complete list of Norstar alarms, consult the Norstar
Alarm & Event Code Manual. Also consult the Modular ICS
Installer Guide.
Displays
Example
display
Meaning Possible causes and actions
Alarm: 21
Wireless re-evaluation
in progress
Scheduled or required re-evaluation
of wireless base stations in system
Alarm: 22
Wireless re-evaluation
complete
Scheduled or required re-evaluation
of wireless base stations in system
Alarm: 53
A single radio has been
removed from service
due to an error. An
accompanying event
message indicates an
explicit reason for the
radio failure.
Alarm: 54
A software download to
the base stations has
started.
Alarm: 55
The base station
download is complete.
Alarm: 68
An upgrade has been
performed.
A trunk or station module has been
added to a system to which base
stations are already connected. The
base stations must be moved to the
highest numbered ports on the
system.
Alarm: 200
Insufficient radio
credits
Alarm: 201
Radio credits
decreased
Alarm: 202
UTAM key required (U.S. only) Valid UTAM Activation
Key required.
Radio data
on page 62