Nortel Networks P0992639 01 SONAR User Manual


 
18 / Installation
Modular ICS Companion Installer Guide P0992639 01
Connecting expansion modules
In order to keep the default port and extension numbering,
connect Trunk Modules to the Expansion Cartridge beginning
at the top and working down; connect Station Modules to the
Expansion Cartridge beginning at the bottom and working up.
Installing Remote Power Interconnect (RPI) units
Installation planning is required for base
stations.
Before connecting any Station Modules required
for base stations, please see
Configuring
expansion modules
on page 8 for more
information on the installation rules involved.
The RPI unit should have the DC backup power
supplied by a UL listed UPS.
The UPS should have an output voltage rating of 44 to
50 V DC, with a maximum fault current limit of 6 A to
protect the RPI output wiring. Otherwise, it may be
necessary to use class 1 wiring.
The RPI units must always be installed inside a
building.
The AC outlet powering the RPI should be installed near
the equipment and should be easily accessible.
The length of the RPI cord, from the outside surface of
the unit to the plug, should be a minimum of 1.3 m (4 1/
2 ft.) and a maximum of 4.6 m (15 ft.).