P0992639 01 Modular ICS Companion Installer Guide
Position base stations away from an office area or where a
portable is used by at least the amounts shown in the following
table. Installing the base station on the ceiling or high on walls
helps to maintain these minimum distances.
Minimum distance between office areas and base stations
Mounting a base station
Base stations can be mounted on a wall or on a ceiling. When
mounting on a wall, install them with their covers at the
bottom, as shown in the following illustrations. Allow for
clearances around the base station as indicated in the following
illustration.
Clearance for the base stations
Number of base stations
in the cell
Minimum distance between office
areas and base stations
11 m (40 in.)
2 1.4 m (56 in.)
3 1.8 m (72 in.)
42 m (80 in.)
Clearance conditions Canada USA
Clearance from all other objects 9 cm 3.5 in.
Vertical clearance from base station center to
base station center
27 cm 54 in.
Horizontal clearance from base station center
to base station center
41 cm 54 in.