Omega Engineering FLR7000 series Marine Sanitation System User Manual


 
Installing the Transmitter
1. Disconnect electrical power from the target sys-
tem before making or changing any transmitter
connections.
2. Use 0.05A fast acting fuse if non-current limited
power sources are utilized.
3. Terminate cable shield connection at either DC
ground or Earth ground.
4. Mount the transmitter so fluid is traveling in the
direction of the flow arrow. See Figure 5.
5. Install unit in desired location. Use wrench on
transmitter flats to hold the unit in place during
installation. DO NOT TURN the transmitter
using the wrench. See Figure 6.
6. After installation, rotate transmitter by hand to
view display. See Figure 7.
7. Capture the zero flow position on the meter
cone using the ZERO CAPTURE procedure
found on page 12.
IV. OPERATION
NOTE: Refer to the Appendix for application informa-
tion and fluid charts.
Operating the Meter
The monitor has two modes of operation, referred to
as RUN mode and PROGRAM mode as indicated on
the display screen readout. Normal operation will be in
the run mode. To access the program mode, press the
MENU key until the first programming screen
DISPLAY appears. (PROGRAM appears on left side of
display.) After programming the meter a password may
be entered to prevent unauthorized access or chang-
ing of the setup features.
Normal Operation (RUN) Mode
During normal operation, the display will show RUN
and the flow rate, total flow, or toggle back and forth
between the two as defined by the DISPLAY configu-
ration.
The 4 buttons have the following function in RUN
mode:
MENU - Selects programming mode.
UP ARROW - No function.
RIGHT ARROW - No function.
FLR Flow Transmitter
Installation & Programming Instructions
Page 6
Figure 5. Flow Direction Arrow
Place wrench on
transmitter flats on the
same side plumbing is
being tightened
Never
place wrench
on transmitter flats
opposite plumbing
being tightened
Figure 6. Installing Transmitter
Never use wrench to
rotate transmitter
body when viewing
flow display
Rotate transmitter by
hand to view flow
display
Figure 7. Rotating Transmitter
FLOW
INLET PORT
FLR