3.2.3 System Diagnostics
The System Diagnostics/Statistics screen looks like this:
NOTE: This screen is updated once per second.
The System Diagnostics/Statistics options and functions are described
below.
Local Loop Idle
(default)
The Local Loop is a bi-lateral loopback in which the data from the local
DTE and the data from the remote unit are looped back to their respec-
tive sources (See Section 5.3). Activate this loop to test the each of
the DTE’s connection to the Model 2094.
The Local Loop test has four states:
Idle No user-controlled loopbacks are active.
LL The Model 2094 is in local loopback mode.
Off The Model 2094 is in remote loopback mode or sending
a pattern. Local loopback is disabled.
LocP The Model 2094 is in local loopback mode, and is send-
ing a test pattern.
20
If you do not have a terminal, you may force the unit to use the DIP
switches as the default configuration source by turning off the unit, set-
ting all the DIP switches to the ON position, then powering on the unit.
This will cause the unit to enter a special mode. Then turn off the unit
and change the switch settings to the desired settings. When you turn
the unit on again, the unit will be set up with the selected switch set-
tings.
DS0 Channel Configuration Menu [ Bandwidth/# Channels =
2,048k/na]
(default)
The Channel Configuration Menu has a sub-menu that looks
like this:
You may configure the Model 2094 to operate with any combination of
active and inactive DS0 channels in this screen. When you execute the
Save Changes command, the selected settings will be saved to perma-
nent memory, and the system will be updated to operate with the new
channel settings.
NOTE: In Unframed format, the Bandwidth Selected will display
“2.048k,” and the Total Channels will display “na.” When using the
DIP switches to set the bandwidth, the starting channel is always
channel 1 or 0.
19
n
a