PowerLogic™ PM5500 series user manual Chapter 7—Viewing meter data
HRB1684301-01 63
Power
Related topics
• See “Power demand” on page 115.
Energy
Power
(PQS)
Power (PQS)
Phase
Dmd
Active (P)
Reac (Q)
Appr (S)
VARd (Qd)
Tot
ABC
Wd (Pd)
Tot
ABC
VAd (Sd)
Tot
ABC
Power [PQS]
Power [PQS]
Summary of real-time power consumption values for total active
power in kW (Total [Ptot]), total reactive power in kVAR
(Total [Qtot]), and total apparent power in kVA (Total [Stot]).
Phase Per phase and total power values for active power in kW (A [P1],
B [P2], C [P3], Total [Ptpt]), reactive power in kVAR (A [Q1],
B [Q2], C [Q3], Total [Qtot]) and apparent power in kVA (A [S1],
B [S2], C [S3], Total [Stot]).
Active [P], Reac [Q], Appr [S]
Dmd
Summary of peak power demand values in the previous (Last)
demand interval period for active power in kW, reactive power in
kVAR and apparent power in kVA.
Wd [Pd], VARd [Qd], VAd [Sd]
Total and per phase peak power demand values in the previous
(Last) demand interval for active power demand (Wd [P]),
reactive power demand (VARd [Q]) and apparent power demand
(VAd [S]).
Tot, A [1], B [2], C [3]
For the selected power demand screen (active, reactive or
apparent), each of these sub-screens (total and per phase
demand) display demand values for the present demand (Pres)
interval, predicted demand (Pred) based on the current power
consumption rate, demand for the previous demand (Last)
interval period, and recorded peak power demand (Peak) value.
Pk DT Date and timestamp for the peak power demand (Peak) value.
Energy
(E)
Wh
VAh
VARh
Inp Mtr
Tariff
T1
T2
T3
T4
T5
T6
T7
T8
Dmd
Ch 1
Ch 2
Ch 3
Ch 4
Energy [E]
Wh Delivered (Del), received (Rec), delivered plus received (D+R)
and delivered minus received (D-R) accumulated values for
active energy (Wh), apparent energy (VAh) and reactive energy
(VARh).
VAh
VARh
Tariff
Displays the available tariffs (T1 through T8).
T1, T2, T3, T4, T5, T6, T7, T8
Del
Active energy delivered in Wh (W [P]), reactive energy delivered
in VARh (VAR [Q]) and apparent energy delivered in VAh
(VA [S]) energy for the selected tariff.
Rec
Active energy received in Wh (W [P]), reactive energy received in
VARh (VAR [Q]) and apparent energy received in VAh (VA [S])
energy for the selected tariff
InMet
Accumulated values on the input metering channels (Ch 1 to
Ch 4) for the selected tariff.
Inp Mtr
Accumulated values on the input metering channels (Ch 1 to
Ch 4).
Dmd
Summary of demand values for input metering channels Ch 1 to
Ch 4 in the previous (Last) demand interval.
Ch 1, Ch 2, Ch 3, Ch 4
Demand values for present (Pres) and previous (Last) interval
periods, predicted demand (Pred) based on the current
consumption rate, and recorded peak demand (Peak) value for
the selected input metering channel.
Pk DT Date and timestamp for the peak demand reading.