Standard Horizon MDS-10-4 Marine RADAR User Manual


 
Radar Installation Manual Page 17
2. Move the ShuttlePoint knob to highlight ADVANCED SETUP and press [ENT].
3. Move the ShuttlePoint knob to highlight
IN/OUT CONNECTIONS and press [ENT].
4. Move the ShuttlePoint knob to highlight
PORT 1 INPUT and press [ENT].
5. Move the ShuttlePoint knob up/down to select
RADAR and press [ENT].
6. Press [CLR] or move the ShuttlePoint knob to the left until the Chart page is shown.
2.7.1 CP300 & CP300i Connections
PWR & ACC 1 Cable
A switch MUST be connected
to turn the Radar On or Off
Radar
Switch
Battery
Battery Switch
RADAR CABLE
WIRE COL. FUNCTION
BLACK DATA GROUND
ORANGE DATA OUT+
YELLOW DATA OUT-
BROWN DATA IN+
RED DATA IN-
GREEN POWER ON/OFF SWITCH
BLUE POWER ON/OFF SWITCH
BLACK RADAR BATTERY GROUND
WHITE RADAR BATTERY POSITIVE
PLOTTER CABLE
WIRE COLOR FUNCTION
GREEN GND
No connection AUX OUT+
(Port1) OUTPUT+ (TX+)
BLUE (Port 1) INPUT+ (RX+)
BLACK POWER- /GND
RED POWER+
BROWN
Breaker panel
Figure 2.7.1 - CP300 & CP300i Connections
Port Setup
When an optional Radar Antenna is connected, Port 1 of the NMEA In/Out Communication
Setup menu must be changed to RADAR as shown below for communications.