Yamaha F6A Outboard Motor User Manual


 
1-14
E
EMU01430¯
BATTERY REQUIREMENT
CAUTION:
@
Do not use a battery that does not meet
the specified capacity. If a battery which
differs from the specification is used, the
electrical system may perform poorly or
be overloaded, causing electrical sys-
tem damage.
@
CAUTION:
@
A battery cannot be connected to mod-
els which do not have a rectifier or rec-
tifier regulator.
Models without a rectifier or rectifier reg-
ulator: F6MHA/F8MHA
If you wish to use a battery with the
above models, install an optional recti-
fier regulator.
Choose a battery for electric start models
which meets the following specifications.
Minimum cold crank performance
380 Amps at 17.8 °C (0 °F)
Minimum reserve capacity
124 minutes at 26.7 °C (80 °F)
U68T13.book Page 14 Wednesday, August 8, 2001 12:37 PM