Aiphone IE-SSR Marine Radio User Manual


 
NOTE:
For complete AX system information, please refer to the installation manual provided
on the CD packaged with the CEU, or access from our web site at www.aiphone.com.
- INSTRUCTIONS -
The IE-SS/A and IE-SSR are vandal proof and weather resistant sub stations designed for use with the systems listed
above. They're constructed with 12 gauge stainless steel, and the IE-SSR features a red mushroom call button. The
units either flush mount into a 2-gang box, or surface mount with the SBX-2G. Each unit includes tamper proof screws
and a tool for installation.
Vandal Resistant Sub Stations for AX, IE, TD-H, TC-M Systems
WIRING DIAGRAM (AX Series):
MOUNTING:
IE-SS/A
(or IE-SSR)
TORX
screws
2-GANG BOX
INSTALLATION:
1. For flush mounting, install sub station in standard 2-gang electrical box with min. 2-1/2" depth.
2. For surface mounting, install sub station in the SBX-2G surface mount enclosure.
3. IMPORTANT! These units are designed for use in normal weather conditions, and to allow drainage and
evaporation of moisture that naturally gets into the unit. Do not apply caulking or silicone sealant around the
unit when installing, and do not use weather stripping around the perimeter of the box when mounting. If
sealing the unit is required, the bottom must remain unsealed.Sealing the unit will prevent or inhibit moisture from
dissipating from inside the unit, which may cause corrosion or deterioration to the internal components over time.
Do not apply
sealant between
unit and box.
Pg. 1
IE-SS/A / IE-SSR
Red
Blk
NOTE:
1 PS-2420UL per system
when all subs are audio-only.
If any video door stations are
on the system, 2 PS-2420UL
power supplies are required.
CAT-5e
CAT-5e
Note: Wire from sub can be 2-
conductor, but must be spliced to
CAT-5e with RJ-45 jack at CEU.
AX Central Exchange Unit
Homerun each sub to
AX-084C, AX-248C, or
AX-320C CEU.
Red
Blk
IE-SS/A / IE-SSR
TIA/EIA 568B Standard:
Connect 3/6 pair (green) to “Red”
Connect 7/8 pair (brown) to “Black”
CAT5e
Illustration of converting from
2-conductor to CAT-5e cable.
Use your preferred method for splicing cables to
interface a standard 2-conductor cable run from
the door station to the CAT-5 cable and RJ45
jack, required for connection to the CEU.
IE-SS/A IE-SSR