Audible and Visual Alarms
The RG Battery Backup alarms to indicate certain events.
Front-Panel
Label
Visual
Indicator
Audible
Alarm
Description
ON A/C Green LED
lights
None The RG Battery Backup is
operating on A/C.
Testing
Battery
Green LED
flashes
None The RG Battery Backup is conduct-
ing a self-test. This automatic
procedure is normal and will occur
when the unit is switched on,
and periodically thereafter. This
procedure will last approximately 5
minutes.
ON
Battery
Yellow LED
lights
Tone every
5 seconds
The RG Battery Backup is
operating on battery power.
The alarm will stop when main
power is returned.
Low
Battery
Yellow LED
flashes
Tone every
1 second
The battery energy is running low.
This alarm will continue until the
unit performs a forced shutdown
when the battery is depleted.
Replace
Battery
Red LED
flashes
Tone every
2 seconds
This alarm warns that the battery
has reached the end of its useful
life. The user must replace the
battery as soon as possible to
ensure proper operation of the
RG Battery Backup.
Fault Red LED
lights
Continuous
tone
A fault has occurred. Disconnect
equipment from the RG
Battery Backup prior to
checking equipment.
NOTE: Audible alarm will not sound when mute switch is in ON position.