Belkin F5C412uk140W Marine Battery User Manual


 
Additional Safety Features:
1. Automatic shutdown when the internal circuit temperature exceeds
standard design parameters for safe operation.
2. Continuous audible alarm:
a. When the input power from the 12-volt power source drops to 11 volts.
b. When the internal circuit temperature exceeds standard design parameters
for safe operation.
In the event of automatic shut-down or continuous alarm, turn the Inverter
rocker switch to the OFF (O) position until the source of the related problem
has been identified and resolved.
Note:
The Belkin 300W model is equipped with a cooling fan that is only designed
to run continuously while the Inverter is operating. Automatic shutdown
caused by excess circuit temperature occurs when the cooling fan is unable to
maintain the design parameters for safe operation of the Inverter.
To maintain your Inverter in proper working condition, note the following
important safety precautions:
MOISTURE - Keep the Inverter dry. Do not expose it to moisture.
HEAT – The ambient air temperature should be between 50ºF and 80ºF,
(approx. 17ºC - 27ºC). Avoid placing the Inverter on or near heat source.
Do not place the Inverter in direct sunlight.
VENTILATION – In order to disperse the heat generated while the Inverter
is in operation, keep it well ventilated. While in use, maintain several
inches of clearance around the top and sides of the Inverter.
Caution:
Most automobole cigarette lighter circuits use
fuses rated at 10-20 Amps.
Battery Direct-Connect Cables:
For the Belkin 300-Watt Inverter Only – F5C412uk300W
Note:
If the equipment or appliance you intend to operate requires more than
150 Watts of continuous power, the Belkin 300-Watt Inverter should be
connected directly to the power source using the Battery Direct-Connect
Cables. Failure to do so may result in serious damage to the power cord or
to the cigarette lighter socket wiring in your vehicle.