Dakota Digital UTV-1500 Marine Instruments User Manual


 
page 4 MAN#650265
Follow the steps below for gauge setup:
1. Press and hold the switch while turning the key on. (If calibrating speed press and hold switch while starting engine.)
2. Release switch. Gauge will scroll through the main menu options.
3. When the desired option is displayed, press and release the switch to enter menu option.
4. Gauge will scroll through submenu options. Press and release the switch to enter submenu option.
5. In submenu option, press and release the switch to change setting. Press and hold switch to save setting.
6. Select “done” from submenu to return to main menu.
7. Select “done” from main menu to leave setup menu. Setup can be left at anytime by turning off key
SETUP MENU GUIDE:
 Release switch to enter setup menu
 Information menu
 Displays software version
 Current software version
  Displays current speed cal value
 Current speed cal value
 Returns to main menu
 Speed gauge menu
 Select unit for speed
Toggle between MPH and km/h (select unit to use for calibration)
 Auto calibrate speedometer to a marked mile or kilometer
Displays  on speed and speed pulses in odometer
Press switch to save value and leave setup
 Adjust speed cal while driving
 Each press of switch toggles direction of adjustment, value saved after 8 sec no switch
SERV  Sets value of service odometer set when service odometer is reset
 ( ) Turns off the count down service odometer (default)
 ( ) Sets service to 500 mi or 800 km when resetting service odometer.
…. Service point can be set in 500 mi (800km) increments.
 () Sets service to 7500 mi or 12000 km when resetting service odometer.
 Returns to main menu
 Tachometer gauge menu
 Sets tachometer input type
  number of cylinders from 1-15 (default 12 for stock tach input)
SERV  Sets service hour value used when resetting count down service hour meter
 Service hour meter disabled (default)
 Minimum service hour set point
Service hour reset point can be set in 10 hr increments
 Maximum service hour set point
 Returns to main menu
 Gauge option menu
VOLTS   Set high voltage warning point (default 15.4V)
VOLTS   Set low voltage warning point (default 11.1 V)
OIL   Set low oil pressure warning point (default 9 PSI)
TEMP   Set high water temp warning point and set temperature unit (default 230F)
  ( ) Select temp unit, press switch to change, hold switch to save
TEMP   Select high warning, press switch to change, hold switch to save
 Returns to main menu
SETUP MENU GUIDE (continued):
 Option menu