Desa VSLR24 Marine Radio User Manual


 
901268-01D
13
13
For more information, visit www.desatech.com
For more information, visit www.desatech.com
WARNING: If you smell gas
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbors phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier, call the fire department.
POSSIBLE CAUSE
1. Metal expanding while heating or con-
tracting while cooling
1. Log set burning vapors from paint, hair spray,
glues, cleaners, chemicals, new carpet, etc.
(See
IMPORTANT
statement above)
2. Gas leak. See Warning statement
above
1. Gas leak. See Warning statement at
above
2. Control valve defective
1. Gas leak. See Warning statement at
above
OBSERVED PROBLEM
Log set produces a clicking/ticking noise
just after burner is lit or shut off
Log set produces unwanted odors
Gas odor even when control knob is in
OFF position
Gas odor during combustion
REMEDY
1. This is common with most log sets. If noise
is excessive, contact qualified service person
1. Open flue to maximum. Stop using odor
causing products while log set is running
2. Locate and correct all leaks (see Check-
ing Gas Connections, page 6)
1. Locate and correct all leaks (see Check-
ing Gas Connections, page 6)
2. Replace control valve
1. Locate and correct all leaks (see Check-
ing Gas Connections, page 6)
IMPORTANT:
Operating log set where impurities in air exist may create odors. Cleaning supplies, paint,
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes
may mix with combustion air and create odors. These odors will disappear over time.
TROUBLESHOOTING
Continued