Emerson BW1 Outboard Motor User Manual


 
IntelliGear Plus Variable Speed MD Gearmotors
5
1.5 - Description of cables and protection devices (Customer Supplied)
NOTICE: When using a circuit-breaker, it must be a motor circuit-breaker (D curve).
• Complywiththesizeofprotectionfuses.
• Thecablesizemayvaryaccordingtolegislationapplicableinthecountry,whichwilltakeprecedenceoverthevalues
given in the table below without exception.
1.6 - UL conformity
1.6.1 Special mains supply
The drive can be incorporated in an installation with short circuit capacity of 5000 A rms maximum at voltage 264 VAC rms
maximum for 230 V (TL) drives or 528 VAC rms maximum for 400 V (T) drives.
1.6.2 Cables
Only class 1 copper cables 60/70° C (140/167° F) should be used.
1.6.3 Fuses
UL conformity is adhered to if the fuses are UL-listed, fast-blow fuses (class CC up to 30 A) with a rating as indicated in
the above table and if the short-circuit symmetrical current does not exceed 5 kA.
1.4 - Radio-frequency interference:
1.4.1 - General
Variable speed drives use high-speed switches (transistors,
semi-conductors) which switch high voltages (around
660V for 3-phase drives) at high frequencies (several kHz).
This provides better efficiency and a low level of motor
noise. As a result, they generate radio-frequency signals
which may disturb operation of other equipment or distort
measurements taken by sensors:
•duetohighfrequencyleakagecurrentswhichescape
to ground via the stray capacity of the drive/motor cable
and that of the motor via the metal structures which
support the motor
•byconductionorfeedbackofR.F.signalsonthepower
supply cable; conducted emissions
•bydirectradiationneartothemainsupplypowercable
or the drive/motor cable: radiated emissions
These phenomena are of direct interest to the user. The
frequency range concerned (radio-frequency) does not
affect the energy distribution company.
1.4.2 - Standards (Emission)
The maximum emission level is set by (EN 50081-2) and
(EN 50081-1). IntelliGear Plus conforms to:
•EN50081-2asstandard
•EN50081-1withlteroption
1.4.3 - Standards (Immunity)
The maximum immunity level is set by (EN 50082-2) and
(EN 50082-1). IntelliGear Plus conforms to:
•EN50082-2andEN50082-1asstandard
Motor 115V Single Phase Power Supply 230V Single Phase Power Supply
HP Rating
IntelliGear
Plus Number
Input Amps Wire Gauge Fuse Size IntelliGear
Plus Number
Input Amps Wire Gauge Fuse Size
0.50 I 310M 050 5 14AWG 10 A I 31M 050 2.5 14AWG 8A
0.75 I 32M 075 8.5 14AWG 14A I 31M 075 4 14AWG 8A