Installation Guidelines
A typical installation and connection routine for the FR380RC Low Voltage searchlight is as
follows:
Referring to wiring diagram C23291, a supply is fed to the control panel, which then provides a
common feed to the motor gearbox and the searchlight.
The searchlight has been pre-wired with 3 meters of cable from the gearbox to junction box
provided.
Cables required to be connected by the customer: -
4 core 1.5mm cable from the junction box to the Control Panel.
12 core 0.5mm cable from the junction box to the Control Panel.
The Mains cable to the Control Panel to be supplied by the customer. The searchlight head is pre-
wired along with the connecting cable to the motor gearbox.
A typical installation and connection routine for the FR300RC High Voltage searchlight is as
follows:
Referring to wiring diagram C23293, a supply is fed to the control panel, which then provides a
common feed to the motor gearbox and the searchlight.
The searchlight has been pre-wired with 3 meters of cable from the gearbox to junction box
provided.
Cables required to be connected by the customer: -
4 core 1.5mm cable from the junction box to the Control Panel.
12 core 0.5mm cable from the junction box to the Control Panel.
The Mains cable to the Control Panel to be supplied by the customer. The searchlight head is pre-
wired along with the connecting cable to the motor gearbox.