Furuno 1935 Marine RADAR User Manual


 
1-4
Antenna unit, cover removed
How to fasten the radome base to the platform
Wiring and preparation
4. Make a hole of at least 20 millimeters in diameter through the deck or bulkhead to run the sig-
nal cable. (To prevent electrical interference, do not run the signal cable near other electrical
equipment. Do not run the cable in parallel to power cables.) Set the cable through the hole.
Close the hole with the sealing compound for waterproofing.
5. Remove three shield covers in the radome.
Flat washer
Spring washer
M10 x 25 Hex bolt
Platform
Ship's bow
Cable
entry
1-ø16 Hole
4-ø12
Holes
Platform
Ship's bow
Cable
entry
1-ø16 Hole
Flat washer
Spring washer
M10 x 25 Hex bolt
4-ø12
Holes
Antenna unit: RSB-0071-057
XN10A-RSB-0070/0073-064
XN12A-RSB-0070/0073-059
Antenna unit: RSB-0071-057A
XN10A-RSB-0070/0073-064A
XN12A-RSB-0070/0073-059A
Flat
washer
Spring
washer
Platform
Antenna base plate
M10 x 25
Hex bolt
Radome
5 - 10 mm
Apply silicone sealant.
Effective
thread length
25 mm
Gasket