4-18
DIP switches settings on each board
Factory Setting
PCB
Symbol
No.
No. ON OFF
Functions
1ONMEA
OFF: Ver 2.0 (With check sum at last output data
ON: Ver. 1.5 (Without check sum)
2ONo use
3 O Log pulse out
OFF: Forward only
ON: Forward and backward
4ONo use
5O
6O
Receive data format for AUX port (Effective when
S2-1/2 are set to ON.)
DAT1: TKC (<CR>DDDdd)
DAT2:TKC (DDDd*<LF>)
DAT3: Hokushin ($HERHRC, DDDdd,+/-RRr*cs)
7 O Depth data format
OFF: CIF
ON: NMEA
S1
8 O Temperature data format
OFF: CIF
ON: NMEA
1O
2O
Bearing data format
3 O Log pulse measurement layer
OFF: Reference layer
ON: 1st layer
4 O Set to ON when S1 #3 is off.
5 O Bearing output at slow speed (less than 0.5 kts)
OFF: True bearing
ON: Heading
6 O Bearing output data
OFF: True bearing
On: Heading
7 O Signal level of AUX port
OFF: Current loop
ON: RS-232C
JIFA
66P3800
S2
8 O CIF data ON/OFF
OFF: Standard
ON: Option
5 OFF ON OFF ON
6OFFOFFONON
Data undefined DAT3 DAT2 DAT1
1 OFF ON OFF ON
2OFFOFFONON
Sensor ADC CIF NMEA AUX
ADC: AC converter (Furuno clocked-serial)