(160 6.3")
(100 3.9")
(120 4.7")
4– ø12
370 14.6"
447 17.6"
291 11.5"
90
3.5"
42
1.7"
319 12.6"
293 11.5"
126 5.0"
Output: Water depth $SDDBT, $SDDPT
Water temperature* $YCMTW
Speed* $VWVHW
8. Output Power (Specify when ordering)
1, 2 or 3 kW rms
POWER SUPPLY (Specify when ordering)
10.5 - 20.0 VDC or 18 - 40.0 VDC, less than 45 W
115/230 VAC with optional rectifier PR-62
POWER CONSUMPTION
45 W (1 kW), 48 W (2 kW), 50 W (3 kW)
ENVIRONMENT (IEC test method)
Temperature: -15° C to +55° C (IEC 945)
Water resistance: IPX2 (IEC 529)
(protected against dripping water)
EQUIPMENT LIST
Standard
1. Display Unit CV-291/CV-292 1 unit
(Specify output power and power supply when ordering)
2. Installation materials and standard spare parts 1 set
Optional
1. Speed & temperature sensor ST-01MSB (Thru-hull, bronze)
2. Temperature sensor T-02MSB (Thru-hull, bronze)
3. EMI filter FP02-03900
4. NMEA cable MJ-A6SPF0012-050 (5 m)
5. Rectifier PR-62 for 115/230 VAC mains
TRANSDUCERS
Specify operating frequencies when ordering. Select one
for FCV-291, two for FCV-292.
1 kW 2 kW 3 kW
28 kHz: 28F-8 28F-18 28F-24H
50 kHz: 50B-9B 50B-12 50F-24H
88 kHz: 88B-8 88B-10 88B-126H
200 kHz: 200B-8B 200B-8B 200B-12H
SPECIFICATIONS OF FCV-291/FCV-292
0009XN Printed in Japan
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
1. Display
10" color CRT, 232 x 240 pixels, 16-colors
2. Display Modes
Single for FCV-291
Single LF or HF or Dual for FCV-292
Common features to FCV-291/292: Marker Zoom,
Bottom-Lock, Bottom Discrimination, Bottom Zoom,
A-scope (HF in dual mode for FCV-292) and NAV data
3. Frequency
FCV-291: Single frequency to choose from 28, 38*, 50, 88
or 200 kHz
FCV-292: Dual frequencies to choose from 28, 50, 88
or 200 kHz
* 38 kHz transducer must be arranged locally.
4. Range Settings
Basic Range (Factory setting)
m 5, 10, 20, 40, 80, 150, 300, 500
ft 15, 30, 60, 120, 200, 400, 1000, 1500
fa 3, 5, 10, 20, 40, 80, 150, 250
p/b 3, 5, 10, 20, 40, 80, 150, 250
(Range scales can be selected from 5 to 4,000 m
in Menu)
Zoom Range
x2, x3, x4 or x5
Phased Range
Up to 4,000 m (9,000 ft, 2,000 fa, 2,000 p/b) in 1 to 100 m
(ft, fa, p/b) steps depending on selected range
5. Pulselength and Pulse Repetition Rates
Range (m) 5, 10, 20, 40, 80, 150, 300, 500
P/L (ms) 0.1 0.1 0.1 0.2 0.4 0.7 1.5 2.0
PRR 600 600 600 375 187 110 50 38
6. Picture Advance
Freeze, 1/16, 1/8, 1/4, 1/2, 1/1, 2/1 scan lines/tx
7. Data Interface (NMEA0183) *Optional sensor required
Input:
$- -RMA, $- -RMB, $- -RMC, $- -GLL, $- -VTG, $- -VHW,
$- -MTW, - -XTE, $- -BWC - -: Any talker
10.5 - 20.0 VDC or
18.0 - 40.0 VDC
115/230 VAC
Display Unit
Option
Select one for FCV-291
Select two for FCV-292
Transducers (28/38*/50/88/200 kHz)
ST01-MSB
T-02MSB
Speed/Temp
Sensor
Temperature
Sensor
NAV
GPS
Compass
5 m
03S9148-0, 3.5 m for 10.5 - 20.0 VDC
02S4094-0, 3.5 m for 18.0 - 40.0 VDC
(Specify when ordering)
Rectifier
PR-62
38 kHz Transducer to be procured by user
*
Display Unit CV-291/CV-292
Weight: 12 kg 26.5 lbs
Mounting dimensions
FURUNO U.S.A., INC.
Camas, Washington, U.S.A.
Phone: +1 360-834-9300 Telefax: +1 360-834-9400
FURUNO (UK) LIMITED
Denmead, Hampshire, U.K.
Phone: +44 2392-230303 Telefax: +44 2392-230101
FURUNO FRANCE S.A.
Bordeaux-Mérignac, France
Phone: +33 5 56 13 48 00 Telefax: +33 5 56 13 48 01
FURUNO ESPANA S.A.
Madrid, Spain
Phone: +34 91-725-90-88 Telefax: +34 91-725-98-97
FURUNO DANMARK AS
Hvidovre, Denmark
Phone: +45 36 77 45 00 Telefax: +45 36 77 45 01
FURUNO NORGE A/S
Ålesund, Norway
Phone: +47 70 102950 Telefax: +47 70 127021
FURUNO SVERIGE AB
Västra Frölunda, Sweden
Phone: +46 31-709 89 40 Telefax: +46 31-49 70 93
FURUNO SUOMI OY
Helsinki, Finland
Phone: +358 9 341 7570 Telefax: +358 9 3417 5716