Graco 309525G Marine Heating System User Manual


 
Maintenance
309525G 11
Maintenance
Check reservoir tank fluid level daily. Add fluid as
needed.
Follow pump maintenance instructions in Husky 716
manual.
Follow heater maintenance instructions in VISCON
HP manual.
Troubleshooting
Related Manuals
Refer to the following manuals for detailed equipment information.
Component Manuals This manual available in following languages:
Problem Cause Solution
Fluid leaking out of reservoir tank
when pump is turned off.
Tank overfilled. Do not fill reservoir tank more than
half full.
Fluid fittings leaking. Loose fittings. Tighten fittings after system reaches
desired temperature.
Hose not heating to desired tempera-
ture.
Diaphragm flow rate set too high. Decrease diaphragm pump flow rate.
Problem with VISCON HP heater. See troubleshooting in VISCON HP
heater manual.
Husky 716 pump not operating cor-
rectly.
See troubleshooting in Husky 716
pump manual.
Manual Description
309524 VISCON HP Heater
308981 Husky 716 Diaphragm Pump
309615 Heater Bracket Kit
Manual Language Manual Language
309525 English 309562 Swedish
309559 French 309588 Chinese
309560 Spanish 309589 Korean
309561 German 309590 Japanese