Graco ti18496b Outboard Motor User Manual


 
Operation
3A2012J 29
13. Turn the main air supply ball valve to the closed
position.
14. Turn the catalyst pump pressure relief/recirculation
valve to the pressure relief position. This will relieve
any built up pressure.
15. Verify that the resin pressure relief/recirculation fluid
line is routed to a grounded container, then turn the
pressure relief/recirculation valve to the pressure
relief position.
16. Units with runaway protection only: disable the
prime/flush function by pushing the prime/flush but-
ton on the DataTrak.
17. Engage gun trigger lock.
18. If the front end of the gun was removed, apply
grease to o-rings and front of gun to prevent mate-
rial from curing or sticking to it, then install gun front
end.
F
IG
. 22
F
IG
. 23
F
IG
. 24