22
ERROR MESSAGE & POSSIBLE SOLUTIONS
CABLE NOT CONNECTED :
1. Check that the signal-cable is properly connected, If the connector is loose, tighten the
connector’s screws.
2. Check the signal-cable’s connection pins for damage.
INPUT NOT SUPPORT :
Your computer has been set to unsuitable display mode, set the computer to display mode given
in the following table.
FACTORY PRESET TIMING TABLE:

MODE
RESOLUTION
HORIZONTA
FREQUENCY
(KHz)
VERTICAL
FREQUENCY
(Hz)
1
720×400 @70Hz
31.469 70.087
2
640×480 @60Hz
31.469 59.940
3
640×480 @67Hz
35.000 66.667
4
640×480 @72Hz
37.861 72.809
5
640×480 @75Hz
37.500 75.000
6
800×600 @56Hz
35.156 56.250
7
800×600 @60Hz
37.879 60.317
8
800×600 @72Hz
48.077 72.188
9
800×600 @75Hz
46.875 75.000
10
832×624 @75Hz
49.725 75.000
11
1024×768 @60Hz
48.363 60.004
12
1024×768 @70Hz
56.476 70.069
13
1024×768 @75Hz
60.023 75.029
14
1152×870 @75Hz
68.681 75.062
15
1152×864 @75Hz
67.500 75.000
16
1280×960 @60Hz
60.000 60.000
17
1280×1024 @60Hz
63.981 60.020
18
1280×1024 @75Hz
79.976 75.025
19
1440×900 @60Hz
64.981 60.050
20
1920×1080 @60Hz
66.587 59.934
21
1600×1200 @60Hz
75.000 60.000
22 1400 x 1050 @ 60Hz 64.744 59.948
23 1680 x 1050 @ 60Hz 65.290 59.954