CAUTION:
THE ABOVE CHART IS ONLY A REFERENCE FOR WIRE SIZING. DO NOT USE THIS
INFORMATION TO ACTUALLY SIZE THE WIRE TO YOUR POWER DRIVE. YOU MUST
CONSULT A LICENSED ELECTRICAL CONTRACTOR WHO WILL DETERMINE THE
ACTUAL WIRE SIZE REQUIRED TO SUIT YOUR PARTICULAR APPLICATION.
2. Use plastic zip ties and any other supplies needed to tie off the electrical cords. This protects the cords from abrasion,
sharp objects, water contact and other harm.
WIRING PROCEDURES
Salzer Reversing Switch - 110VAC ( 3/4 HP Motors)
INCOMING POWER to SALZER SWITCH to MOTOR FEED to MOTOR JUNC. BOX
BLACK 3 (3,7,11 jumpered) na na
WHITE 1 (1,5,9 jumpered) na na
GREEN GROUND BAR GREEN / BARE GROUND
2 YELLOW or WHITE T1 & T3
4 ORANGE T2 & T4
8 (6,8 jumpered) BLACK T8
12 (10,12 jumpered) RED T5
Note: To reverse motor direction operation, reverse wiring of Black (T8) & Red (T5) at motor junction box.
For motors greater than 3/4 hp, a higher rated switch must be used. Contact RGC for additional information.
Remote Control - 110 VAC (3/4 HP Motors)
RC MOTOR FEED to MOTOR JUNC. BOX
GREEN / BARE GROUND
YELLOW or WHITE T1 & T3
ORANGE T2 & T4
BLACK T8
RED T5
Note: To reverse motor direction operation, reverse wiring of Black (T8) & Red (T5) at motor junction box.
Motor Specifications
RGC PN:
6500684
HP: 3/4
RPM: 1725
VOLTAGE: 115 / 208-230
AMPS: 8.2 / 4.5-4.1