MOTORISED ZONE VALVES V4043B/C/H
Installation
T
he V4043 Zone Valve must be
positioned where it cannot block any
vent or cold feed when closed. It may
b
e plumbed in at any angle but must
not be mounted so that the
powerhead is below the horizontal
level of the pipework.
If fitted in a confined space, sufficient
ventilation must be available to keep
the valve within its ambient temperature
range and access must be provided to
remove the powerhead if necessary.
Ordering Specification
V4043B1257
Normally open, 22mm compression.
No end switch. No manual lever.
6.9 KV. Maximum close-off differential
pressure 0.55 bar
V4043B1265
As above, but 28mm comp. 8.6 KV.
0.45 bar max. diff. pressure
V4043C1156
Normally closed,
1
/
2
" BSP female. No
end switch. 3.0 KV. 1.38 bar max. diff
V4043H1056
Normally closed, 22mm compression.
SPST end switch. 6.9 KV. 0.55 bar
max differential pressure
V4043H1007
As above but
3
/
4
" BSP connections
V4043H1106
Normally closed, 28mm compression.
SPDT end switch. 8.6 KV. 0.45 bar
max differential pressure
V4043H1080
As above but 1" BSP connections
40001011-002
24VAC motor kit (low voltage applications)
40002737-003
240VAC replacement motor
40003916-001
Replacement powerhead
40003918-006
Plate & ball assembly kit use with
valves that do not have replaceable
heads (Pre 1987)
272752A/U CARD
Replacement Ball & ‘O’ ring kit
Specification
Power Supply : 230VAC 50Hz
Switch Rating : 2.2 Amps
E
lectrical Connections : 1m flying lead, heat resistant cable
Switch Type : See specifications
Ambient Temperature Range : 5 to 50˚C
Flow Temperature : 5 to 88˚C
Static Pressure : 8.6 bar max
Flow Directions : As per arrow on valve body
Standards : CE, UL, CSA
Approvals : 89/336/EEC & 73/23/EEC
Dimensions (mm)
Wiring
Flow Characteristics
A 87
B 98
C 60
D
1
/
2
94
22mm 112
1” 92
28mm 127
MOTOR
BROWN
BLUE
ORANGE
GREY
G/YELLOW
AUX.SWITCH
WHITE 28mm and 1 BSP ONLY
© Honeywell Control Products and Systems, Issue 10, 4.19
Note: Continuous operation of the valve motor at the fully open position is not recommended.
0014_Section 4_dft10_v4.qxd:Section 2_dft9 15/10/07 16:20 Page 40