Humminbird 405SX Fish Finder User Manual


 
26
If your boat remains out of the water for a long period of time, it may take
some time to wet the transducer when returned to the water. Small air
bubbles can cling to the surface of the transducer and interfere with proper
operation. These bubbles dissipate with time, or you can wipe the face of the
transducer with your fingers after the transducer is in the water.
Never leave the 405SX in a closed car or trunkthe extremely high
temperatures generated in hot weather can damage the electronics.
TROUBLESHOOTING
Do not attempt to repair the 405SX yourself. There are no user serviceable parts
inside, and special tools and techniques are required for reassembly to ensure the
waterproof integrity of the housing. Repairs should be performed only by
authorized Humminbird technicians.
Many requests for repair received by Humminbird involve units that do not
actually need repair. These units are returned no problem found. If you have a
problem with your
405SX, use the following troubleshooting guide before calling
your dealer or sending your unit in for repair. The
405SX contains several tools
that can aid in determining if there is a problem and how to isolate and repair the
problem in many cases.
1. Nothing happens when I turn the unit on.
Check the power cable connection at both ends. Be sure the cable is connected
correctly to a reliable power sourcered lead to positive, black lead to negative
or ground. Ensure the power available at the mount is between 10 and 20 VDC.
If the unit is wired through a fuse panel, ensure the panel is powered. Often
accessory fuse panels are controlled by a separate switch or the ignition switch.
Also, often a fuse can appear to be good when in fact is not. Check the fuse with
a tester or replace it with a fuse known to be good.
Check the power connection to the
405SX. It is possible to force the power cable
connector into the cable holder incorrectly. If the connector is reversed, the unit
will not work. Examine the contacts on the back of the unit to ensure there is no
corrosion. Finally, ensure the unit is firmly seated on the mount. The electrical con-
tacts are not made until the unit is fully seated.
Ensure the metal cable retainer is properly installed in the mount. If not, the power
connection may push out when the unit is put on the mount.
MAINTENANCE
MAINTENANCE/TROUBLESHOOTING