Humminbird 531444-1_A Fish Finder User Manual


 
49
Select Readouts
(Advanced, Sonar view only)
Select Readouts sets individual digital readouts on the Sonar View. This Advanced
feature allows you to select what data will be displayed in each of 5 fixed-position
data windows arranged around the left and bottom edges of the Sonar View
screen, or whether a particular window will be turned off, displaying nothing in
that area; you can access this menu choice only when in Advanced User Mode
(see Setup Menu Tab: User Mode.)
Data windows can display readouts from
supported accessories such as Temp/Speed. Each
data window can either be empty or contain one of
the following:
- Speed (will be displayed if a Temp/Speed
Accessory is attached and the paddlewheel has
moved at least once)
- Temperature
- Triplog (will be displayed if a Temp/Speed
Accessory is attached and the paddlewheel has
moved at least once)
- Voltage
- Water Speed (will only be displayed if a
Temp/Speed Accessory is attached and the
paddlewheel has moved at least once).
Select Readouts
Depth Offset
(Advanced)
Depth Offset will adjust the digital depth readout to indicate depth from the
waterline or boat's keel. Enter a positive vertical measurement from the transducer
to the waterline to read the depth from the waterline. Enter a negative vertical
measurement from the transducer to keel to read the depth from the keel. This
menu choice is available only when in Advanced User Mode (see Setup Menu Tab:
User Mode.)
T
o change the Depth Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Depth Offset on
the Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Depth Offset
setting. (-10.0 to +10.0 feet or -3 to 3 meters [International Models only],
Default = 0)
Temp Offset
(Advanced)
Temp Offset will adjust the temperature readout by the amount entered. This menu
choice is available only when in Advanced User Mode (see Setup Menu Tab: User Mode.)
T
o change the Temp Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Temp Offset on
the Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Temp Offset
setting. (-10.0 to +10.0 degrees, Default = 0)
50
531444-1_A - 323_Man_English.qxd 11/5/2005 12:34 PM Page 56