Humminbird Matrix 10 Fish Finder User Manual


 
49
Troubleshooting
Before contacting the Humminbird Customer Resource Center, please read the
following section. Taking the time to review these troubleshooting guidelines may
allow you to solve a performance problem yourself, and therefore avoid sending
your unit back for repair.
Matrix Doesn’t Power Up
If your Matrix doesn’t power up, use the Installation Guide that also comes with it
for specific confirmation details, making sure that:
the power cable is properly connected to the Matrix control head,
the power cable is wired correctly, with red to positive battery terminal and
black to negative terminal or ground
the fuse is operational
the battery voltage of the power connector is at least 10 Volts.
Correct any known problems, including removing corrosion from the battery
terminals or wiring, or actually replacing the battery if necessary.
Matrix Defaults to Simulator with a Transducer Attached
A connected and functioning transducer will cause thenewly-started Fishing System
to go into Normal operating mode automatically. If, when you power up the Fishing
System, it goes into Simulator mode automatically, even though a transducer is
already connected, this means that the control head is not detecting the transducer.
Perform the following troubleshooting tasks:
Using the Installation Guide that also comes with your Fishing System, check
to make sure that the transducer cable is securely connected to the Fishing
System. Reconnect if necessary, and power up the Fishing System again to
see if this fixes the problem.
Replace the non-functioning transducer with a known good transducer if
available and power up the control head again.
Check the transducer cable. Replace the transducer if the cable is damaged
or corroded.