Icom IC-F3GS Marine Radio User Manual


 
5 - 4
5-2 PLL ADJUSTMENT
PLL LOCK
VOLTAGE
1
2
• Operating frequency: 146.000 MHz
• Receiving
• Transmitting
MAIN Connect a digital multi
meter to check point
LV.
2.0 V
1.5–2.5 V
MAIN L11
Verify
ADJUSTMENT ADJUSTMENT CONDITIONS
UNIT LOCATION
VALUE
UNIT ADJUST
MEASUREMENT ADJUSTMENT
L11
PLL lock voltage
adjustment
LV
PLL lock voltage
check point
• MAIN unit
Bottom view
RF power meter