Icom IC-F50 Marine Radio User Manual


 
5 - 1
SECTION 5 ADJUSTMENT PROCEDURES
5-1 PREPARATION
When adjusting IC-F60/F61, the optional CS-F50 ADJ ADJUSTMENT SOFTWARE (Rev. 1.0 or later), *OPC-966 JIG CABLE (modified
OPC-966 CLONING CABLE) are required.
REQUIRED TEST EQUIPMENT
SYSTEM REQUIREMENTS
Microsoft
®
Windows
®
95 or Windows
®
98
RS-232C serial port
ADJUSTMENT SOFTWARE INSTALLATION
q Boot up Windows.
- Quit all applications when Windows is running.
w Insert the cloning software CD-ROM into the appropriate
CD-ROM drive.
e Select Runfrom the [Start] menu.
r Type the setup program name using the full path name,
then push [Enter] key.
(For example; D:\Setup.exe)
t Follow the prompts.
y Program group CS-F50 ADJ appears in the Programs
folder of the [Start] menu.
BEFORE STARTING SOFTWARE ADJUSTMENT
Program the adjustment frequencies, listed in page 5-2, into
the transceiver using with the CS-F50 before starting the
software adjustment. Otherwise, the transceiver can not
start software adjustment.
CAUTION!: BACK UP the originally programed memory
data in the transceiver before progaming the
adjustment frequencies.
When program the adjustment frequencies
into the transceiver, the transceivers memory
data will be overwritten and lose original mem-
ory data at the same time.
STARTING SOFTWARE ADJUSTMENT
q Connect IC-F60/F61 and PC with *OPC-966 JIG CABLE.
w Turn the transceiver power ON.
e Boot up Windows, and click the program group CS-F50
ADJ in the Programs folder of the [Start] menu, then
CS-F50 ADJs
window appears.
r Click Connect on the CS-F50s window, then appears
IC-F60/F61s up-to-date condition.
t Set or modify adjustment data as desired.
Microsoft and Windows are registered trademarks of
Microsoft Corporation in the U.S.A. and other countries.
EQUIPMENT
DC power supply
FM deviation meter
Frequency counter
Digital multimeter
RF power meter
(terminated type)
GRADE AND RANGE
Output voltage : 7.5 V DC
Current capacity : 5 A or more
Frequency range : DC600 MHz
Measuring range : 0 to ±10 kHz
Frequency range : 0.1600 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity : 100 mV or better
Input impedance : 10 M/V DC or better
Measuring range : 110 W
Frequency range : 300600 MHz
Impedance : 50
SWR : Less than 1.2 : 1
EQUIPMENT
Audio generator
Attenuator
Standard signal
generator (SSG)
DC voltmeter
Oscilloscope
AC millivoltmeter
GRADE AND RANGE
Frequency range : 3003000 Hz
Output level : 1500 mV
Power attenuation : 40 or 50 dB
Capacity : 10 W or more
Frequency range : 300600 MHz
Output level : 0.1 µV32 mV
(127 to 17 dBm)
Input impedance : 50 k/V DC or better
Frequency range : DC20 MHz
Measuring range : 0.0120 V
Measuring range : 10 mV10 V