Meade TE827W Marine Radio User Manual


 
Icon Status
Searching for remote sensor signals
Corresponding remote sensor successfully linked
No signals received for more than 15 minutes
TEMPERATURE AND HUMIDITY MODE
The weather station supports up to 3 remote thermo-hygrometers corresponding to a separate channel of the temperature and
relative humidity display. The temperature can be displayed in Celsius (ºC) or Fahrenheit (ºF).
The main unit carries the temperature and humidity sensor and uses this indoors data to calculate an indoors comfort level - Wet,
Comfort or Dry.
A temperature alert function is available for each channel. It can be programmed to sound if the channel temperature exceeds or
falls below the pre-set upper and lower limit.
Note: The temperature alerts have a 0.5 ºC deviation to prevent them from sounding due to small temperature fluctuations that
are close to the set alert value. This means that after the temperature reaches the alert temperature, it will have to fall below the
alert temperature plus the deviation (0.5°C) to activate the alert.
Accessing Temperature and Humidity Mode
From the main unit: Press UP ? or DOWN ? until the IN icon on the upper right will flash.
Viewing Temperature and Humidity for each Channel
Static Display:
In Temperature and Humidity Mode, press the CHANNEL button to recall a different channel.
Channel Auto-Scan Display:
To enable automatic scan of the different channels, press and hold CHANNEL, until the icon is displayed. Each valid
channel will be alternately displayed with a 5 seconds delay.
Recalling of Temperature and Dew Point Displays
In Temperature and Humidity Mode press the SET button to recall temperature and relative humidity or dew point and
relative humidity.
Set the Temperature in Celsius or Fahrenheit. (Does not affect Wind Chill)
In Temperature and Humidity Mode, press and hold
SET to toggle the temperature in Celsius (ºC) or Fahrenheit (ºF).
Activating/Deactivating the Temperature Alerts
In Temperature and Humidity Mode, press the ALARM/CHART to recall a current temperature for the corresponding channel,
the upper temperature alert with ? icon (if disabled, displays OFF), or lower temperature alert with ? icon (if disabled,
displays OFF).
Once the above alerts are displayed, press the UP ? or DOWN ? to enable or disable the corresponding alert.
Programming the Temperature Alerts
• In the Temperature and Humidity Mode, press ALARM/CHART selecting the desired alarm.
• Press and hold ALARM/CHART button until the remote temperature and ? or ? icon starts flashing.
• Adjust the temperature digits for the Temperature Alert using the UP ? or DOWN ? . Press and hold either button for fast
digits advance.
• Press the ALARM/CHART to confirm selection and return to the temperature alert selection screen.
Disabling Temperature Alarm(s)
In the Temperature & Humidity Mode press the ALARM/CHART to disable the alarm(s).
Viewing the Max/Min Channel Temperature and Humidity
In the Temperature & Humidity Mode press the MEMORY button to recall a current temperature and humidity, minimum
temperature and humidity or maximum temperature and humidity at the remote location.
Resetting the Remote Temperature and Humidity Memory
In the Temperature and Humidity Mode, press and hold MEMORY button to clear memory for all channels.
Remote Sensor Status
The wave icon above the current channel display shows the connection status of the corresponding remote sensor:
17