Mercury Marine 899337001 Boat User Manual


 
MAINTENANCE
27
Cleaning Procedure
FABRIC SURFACES
Inflate the air chambers. Clean the fabric with a mild soap and fresh
water solution. Rinse with fresh water and dry thoroughly.
IMPORTANT: Do not use a vinyl preservative on the air chamber
fabric. Chemicals in the preservatives may dry out the fabric.
BOAT HULL
Remove the drain plug. Use a hose to wash out any debris from
the interior. Wash the interior with soap and water. Clean any
debris from the drain valve. Rinse with fresh water and dry
thoroughly. Replace the drain plug.
Deflating
IMPORTANT: When deflating the side air chambers, do not deflate
one side air chamber at a time. When deflating, maintain a
balanced air pressure between air chambers to prevent stress or
potential damage to the inside diaphragms that separate the air
chambers.
b
a
c
14778
d
a - Valve stem
b - Closed position
c - Open position
d - Valve cap
1. Unscrew the valve caps, turn a quarter turn counterclockwise.
2. Push in the valve stem and deflate the keel. Push in the valve
stem and turn the stem a quarter turn clockwise to lock the
valve in the open position.
3. Push in the valve stem and deflate the floor. Push in the valve
stem and turn the stem a quarter turn clockwise to lock the
valve in the open position.