Mitsumi electronic FR-CVL-7.5K to 55K Marine Radio User Manual


 
18
Wiring
1) Connection of power supply and dedicated stand-alone reactor
2) Connection of dedicated stand-alone reactor and power regeneration common converter
Dedicated
Stand-Alone
Reactor Model
Terminal Name
Terminal
Screw Size
Tightening
Torque N•m
Crimping
Terminals
Cables
mm
2
AWG
FR-CVL-7.5K
R/L11, S/L21,
T/L31
M5 2.5 14-5 14 6
FR-CVL-11K M5 2.5 14-5 14 6
FR-CVL-15K M6 4.4 22-6 22 4
FR-CVL-22K M6 4.4 38-6 38 2
FR-CVL-30K M6 4.4 60-6 60 1/0
FR-CVL-37K M10 14.7 100-10 100 4/0
FR-CVL-55K M10 14.7 150-10 150 MCM300
FR-CVL-H7.5K M5 2.5 3.5-5 3.5 12
FR-CVL-H11K M5 2.5 5.5-5 5.5 10
FR-CVL-H15K M5 2.5 14-5 14 6
FR-CVL-H22K M6 4.4 22-6 22 4
FR-CVL-H30K M6 4.4 22-6 22 4
FR-CVL-H37K M8 7.8 38-8 38 2
FR-CVL-H55K M8 7.8 60-8 60 1/0
Note: Wire the cables so that the phase sequence is always identical to those of the wiring in 2) and 4).
Connection in wrong phase sequence will damage the power regeneration common converter.
Dedicated
Stand-Alone
Reactor Model
Terminal Name
Terminal
Screw Size
Tightening
Torque N•m
Crimping
Terminals
Cables
mm
2
AWG
FR-CVL-7.5K
R2/L12, S2/L22,
T2/L32
M5 2.5 14-5 14 6
FR-CVL-11K M5 2.5 14-5 14 6
FR-CVL-15K M6 4.4 22-6 22 4
FR-CVL-22K M6 4.4 38-6 38 2
FR-CVL-30K M6 4.4 60-6 60 1/0
FR-CVL-37K M10 14.7 100-10 100 4/0
FR-CVL-55K M10 14.7 150-10 150 MCM300
FR-CVL-H7.5K M5 2.5 3.5-5 3.5 12
FR-CVL-H11K M5 2.5 5.5-5 5.5 10
FR-CVL-H15K M5 2.5 14-5 14 6
FR-CVL-H22K M6 4.4 22-6 22 4
FR-CVL-H30K M6 4.4 22-6 22 4
FR-CVL-H37K M8 7.8 38-8 38 2
FR-CVL-H55K M8 7.8 60-8 60 1/0
MCNFB
R/L11
Dedicated
stand-alone reactor (FR-CVL
)
S/L21
T/L31
R2/L12
S2/L22
T2/L32
1)
R/L11
Dedicated
stand-alone reactor (FR-CVL)
S/L21
T/L31
R2/L12
S2/L22
T2/L32
R2/L1
S2/L2
T2/L3
2)
FR-CV
10m
(32.81 feet)
maximum