Mustang Survival MSV971 Life Jacket User Manual


 
Mustang Survival MSV971 Life Preserver and Survival Vest
Description and Maintenance Instructions
9 June 2004, Rev: 1.0
Figure 21. Step a. Replace Inflatable Cell
Self-locking Tie
b. Remove the oral inflator valves and CO
2
inflation device from the cell.
c. Reinstall the components removed from the non-serviceable cell onto the
replacement cell.
d. Perform the Inflatable Cell Test detailed in Section 5.7.
e. Re-attach the serviceable cell to the protective container with the cell anchor strip.
Referring to figures 4 and 22 and starting at the right side, thread the aramid cord
loops of the protective container through the grommets of the cell anchor strips. Pass
the first cord loop over the top of the second loop and so forth, forming an
interlocking arrangement as shown.
Figure 22. Step f. Replace Inflatable Cell
28
T
T
h
h
i
i
s
s
d
d
o
o
c
c
u
u
m
m
e
e
n
n
t
t
i
i
s
s
f
f
o
o
r
r
i
i
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
p
p
u
u
r
r
p
p
o
o
s
s
e
e
s
s
o
o
n
n
l
l
y
y
.
.
I
I
t
t
i
i
s
s
n
n
o
o
t
t
a
a
c
c
o
o
n
n
t
t
r
r
o
o
l
l
l
l
e
e
d
d
d
d
o
o
c
c
u
u
m
m
e
e
n
n
t
t
a
a
n
n
d
d
m
m
a
a
y
y
n
n
o
o
t
t
b
b
e
e
c
c
o
o
n
n
s
s
i
i
d
d
e
e
r
r
e
e
d
d
c
c
u
u
r
r
r
r
e
e
n
n
t
t
w
w
h
h
e
e
n
n
p
p
r
r
i
i
n
n
t
t
e
e
d
d
.
.