NEC N8103-102 Marine Battery User Manual


 
38
15. Install the BBU and the disk array controller to the PCI slot of the server as before
and fix it with the screw.
Disk array controller
BBU
Battery cable
Screws
16. Connect all the cables to the server and the disk array controller as before.
17. Install the removed side cover and power cords to recover the original state. Turn
on the power of the server.
18. After OS is booted, check whether the BBU is recognized correctly. For the
checking procedure, see "2. Checking by Utility" in "Chapter 2 Installation of
BBU".
Notice
The battery pack provided as a maintenance part is not charged at all. For
such battery pack, the value of "Voltage" is indicated as "Now Reading..."
on WebPAM.
WebPAM may not able to recognize the battery pack if it is charged only at
the minimum level (or uncharged). If this occurs, charge the battery pack
for six hours or longer. Then reboot the server and try to recognize the
battery pack again by using WebPAM.
Check
The battery pack is recyclable. Contact your service representative for the
recycle.