Nexus 21 1510 Marine Instruments User Manual


 
NEXUS Autopilot 1510 summary of known checkpoints
All Autopilot systems are complex systems dependant of a number of
transducers and control algorithms why faultfinding needs to be done
carefully to lead to correct remedy.
Checkpoints:
Power:
It is essential to Power the Pilot servo and the Pump motor to get
current enough without risk of voltages drops.
Wireing can be effective by using Relay to get shorter length of
cables.
In a system without relay the Nexus system should never be
powered up later than the AP Servo.
To avoid ”backdrain” of current do not connect the Green wire
(+12V) from the Nexus system.
Wire thickness dependant of Power Cable length :
Cable Length
Max. m. (ft)
Wire Area
mm
2
Wire Area
AWG
3 (10) 2,5 14
5 (16) 4 12
7,5 (25) 6 10
12 (40) 8 8
*) Not nessesary
NX2/Nexus
Server
Autopilot
Servo 1510
+12V
+12V
Optional power
switch* for the
AP Servo
Relay
Emergency
switch for the
AP Servo
0V
0V
15A fuse
Power switch
for the Server
3A fuse
=Power Wires
+ -