Oceanic 04.2250.36 Scuba Diving Equipment User Manual


 
21
BUD OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5259-r01 (7/21/11)
CAN BE USED AS
Dive Computer (Air or Nitrox)
DIVE COMPUTER PERFORMANCE
Buhlmann ZHL-16c based Z+, or DSAT based, algorithm
No Deco limits closely follow PADI RDP
Decompression in agreement with Buhlmann ZHL-16c and French MN90
No Deco Deep Stops - Morroni, Bennett
Deco Deep Stops (not recommended) - Blatteau, Gerth, Gutvik
Altitude - Buhlmann, IANTD, RDP (Cross)
Altitude corrections and O2 limits based on NOAA tables
OPERATIONAL PERFORMANCE
Function: Accuracy:
Depth ±1% of full scale
Timers 1 second per day
Dive Counter:
Displays Dives #1 to 12
Resets to Dive #1, upon diving (after 24 hours with no dives)
Altitude:
Operational from sea level to 14,000 feet (4,270 meters) elevation
Measures ambient pressure every 30 minutes when inactive, upon activation, every 15 minutes while activated.
Does not measure ambient pressure when Wet.
Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Power:
(1) 3 vdc, CR2430, Lithium battery (Panasonic or equivalent)
Shelf life Up to 5 years (dependent on battery manufacturer)
Replacement User (annual recommended)
Use Life 100 dive hours if (1) 1 hour dives per dive day to 300 hours if (3) 1 hour dives per day
Battery Icon:
Warning - icon on solid at 2.75 volts, Battery change recommended
Alarm - icon on ashing at 2.50 volts, change the Battery
Activation:
• Manual - push button (recommended).
• Automatic - when wet.
• Cannot be manually activated deeper than 4 FT (1.2 M).
• Cannot operate at elevations higher than 14,000 feet (4,270 meters)
Operating Temperature:
Out of the water - between 20 °F and 140 °F (-6 and 60 °C).
In the water - between 28 °F and 95 °F (-2 and 35 °C).
TLBG segments
• No Deco Normal zone 1 to 3
• No Deco Caution zone 4
• Decompression zone 5 (all)
VARI 60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments FPM MPM segments FPM MPM
0 0 - 10 0 - 3 0 0 - 20 0 - 6
Normal zone 1 11 - 15 3.5 - 4.5 1 21 - 30 6.5 - 9
Normal zone 2 16 - 20 5 - 6 2 31 - 40 9.5 - 12
Normal zone 3 21 - 25 6.5 - 7.5 3 41 - 50 12.5 - 15
Caution zone 4 26 - 30 8 - 9 4 51 - 60 15.5 - 18
Too Fast zone (ashing) 5 (all) > 30 > 9 5 (all) > 60 > 18
NUMERIC DISPLAYS: Range: Resolution:
Dive Number 0 to 12 1
Surface Interval Time 0:00 to 23:59 hr:min 1 min
Time to Fly & Desat 23:50 to 0:00 hr:min* 1 min
(* starting 10 min after the dive)
FO2 Set Point Air, 21 to 50 % 1 %
PO2 Value 0.00 to 5.00 ATA .01 ATA
Depth 0 to 330 FT (100 M) 1 FT (.1/1 M )
Elapsed Dive Time 0:00 to 9:59 hr:min 1 min
Dive Time Remaining 0:00 to 9:59 hr:min 1 min
Safety Stop Time 0:00 to 3:00 min:sec 1 sec
Deco Stop Time 0:00 to 9:59 hr:min 1 min
Total Ascent Time 0:00 to 9:59 hr:min 1 min
Violation Countdown Timer 23:50 to 0:00 hr:min 1 min
MOD (Max Operating Depth): 330 FT (100 M)
SPECIFICATIONS