Oceanic 04-8791-79 Scuba Diving Equipment User Manual


 
73
OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r01 (6/27/13)
SPECIFICATIONS (CONTINUED)
NUMERIC DISPLAYS: Range: Resolution:
• Time of Day 0:00:00 to 23:59_59 hr:min_sec 1 second
• Dual Time 0:00 to 23:59 hr:min 1 minute
• Dual Time Differential - 23 hr to 0 to + 23 hr 1 hour
• Watch Countdown Timer 23:59 to 0:00 hr:min 1 minute
• Watch Chrono Lap # 1 to 9 1 (Lap)
• Watch Chrono Lap Time 0:00:00.00 to 9:59:59.99 .01 second
hr:min:sec_ .01 sec
• PC Countdown Timer 1:59 to 0:00 min:sec 1 second
• Temperature 0 to 140°F (-18 to 60°C) 1°F (C)
• Compass Heading 000 to 359° 001°
• Compass Declination 0 to +/- 45°
• Altitude Level Sea, EL 2 to EL 7 1 (level)
• Time to Fly 23:50 to 0:00 hr:min 1 minute
• Time to Desat 23:50 to 0:00 hr:min 1 minute
• Depth & Max Depth 0 to 495 FT (150 M) 1 FT (0.1 M )
NORM, GAUG
• Dive Number 0 to 24
• Surface Interval Time 0:00 to 23:59 hr:min 1 minute
• Pressure 0 to 5000 PSI (345 BAR) 5 PSI (1 BAR)
• Elapsed Dive Time 0:00 to 9:59 hr:min 1 minute
• Air Time Remaining 0 to 99 min 1 minute
NORM only
• DTR (NDC, OTR) 0:00 to 9:59 hr:min 1 minute
• FO2 Value (setting) Air, 21 to 100 % 1 %
• PO2 Value 0.00 to 5.00 ATA .01 ATA
• O2 Saturation 0 to 100 % 1 %
• No Deco Deep Stop Time 2:00 to 0:00 min:sec 1 second
• No Deco Safety Stop Time 5:00 to 0:00 min:sec 1 second
• Deco Stop Time 0:00 to 9:59 hr:min 1 minute
• Total Ascent Time 0:00 to 9:59 hr:min 1 minute
• Violation Countdown Timer 23:50 to 0:00 hr:min 1 minute
GAUG only
• Dive Run Timer 0:00 to 9:59 hr:min 1 minute
FREE, TECH FREE
• Dive Number 0 to 99 1
• Surface Interval Time 0:00 to 59:59 min:sec 1 second
1:00 to 23:59 hr:min 1 minute
• Countdown Timer 9:59 to 0:00 min:sec 1 second
• Run Timer 0:00 to 9:59 min:sec 1 second
• Elapsed Dive Time 0:00 to 9:59 min:sec 1 second
WARNING: If your OCi stops working for any reason while operating as a Dive Computer, it is important that
you have anticipated this possibility and are prepared for it. This is an important reason for not pushing the no
decompression and oxygen exposure limits, and a critical reason to avoid entering decompression.
If you dive in situations where your trip would be ruined or your safety would be jeopardized by losing the use of
your OCi, a backup instrument system is highly recommended.
BAR GRAPHS
TLBG segments O2BG segments
• No Deco Normal zone 3 • Normal zone 3
• No Deco Caution zone 1 • Caution zone 1
• Decompression zone 1 • Danger zone 1
VARI 60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments FPM MPM segments FPM MPM
0 0 - 10 0 - 3 0 0 - 20 0 - 6
• Normal Zone 1 11 - 25 3.5 - 7.5 1 21 - 50 6.5 - 15
• Caution Zone 2 26 - 30 8 - 9 2 51 - 60 15.5 - 18
• Too Fast Zone (flashing) 3 (all) > 30 > 9 3 (all) > 60 > 18