Oregon Scientific BAR628HG / BAR628HGU Marine Radio User Manual


 
7
EN
RESET SYSTEM
The RESET button is located in the main unit battery
compartment. Press RESET when you change the
batteries and whenever performance is not behaving as
expected (for example, unable to establish radio
frequency link with remote sensor or clock).
SAFETY AND CARE
Clean the product with a slightly damp cloth and alcohol-
free, mild detergent. Avoid dropping the product or
placing it in a high-traffic location.
WARNINGS
This product is designed to give you years of service if
handled properly. Oregon Scientific will not be responsible
for any deviations in the usage of the device from those
specified in the user instructions or any unapproved
alterations or repairs of the product. Observe the following
guidelines:
Never immerse the product in water. This can
cause electrical shock and damage the product.
Do not subject the main unit to extreme force,
shock, or fluctuations in temperature or humidity.
Do not tamper with the internal components.
Do not mix new and old batteries or batteries of
different types.
Do not use rechargeable batteries with this product.
Remove the batteries if storing this product for a
long period of time.
Do not scratch the LCD display.
NOTE The technical specification of this product and
contents of this user guide are subject to change without
notice. Images not drawn to scale.
TROUBLESHOOTING
PROBLEM SYMPTOM REMEDY
Calendar Strange date / Change language
month (5)
Clock Cannot adjust clock Disable clock (5)
Cannot auto- 1. Adjust batteries
synchronize the (4)
date and time 2. Press RESET
(7)
3. Manually activate
clock feature (5)
Temp Shows “LLL” or Temperature is
“HHH” out-of-range
Remote Cannot locate Check batteries(5)
sensor remote sensor Check location (5)
Cannot change Check sensors. Only
channel one sensor is
working (5)
Data does not Initiate a manual
match main unit sensor search (5)
SPECIFICATIONS
MAIN UNIT DIMENSIONS
L x W x H 116 x 55 x 127 mm
(4.6 x 2.2 x 5 inches)
Weight 186 g (6.6 ounces) without
battery
REMOTE SENSOR DIMENSIONS
L x W x H 92 x 60 x 20 mm
(3.6 x 2.4 x 0.79 inches)
Weight 63 grams (2.22 ounces)
without battery
TEMPERATURE
Unit °C / °F
Indoor range -5°C to 50°C
(23°F to 122°F)
Outdoor range -20°C to 60°C
(-4°F to 140°F)
Resolution 0.1°C (0.2°F)
RELATIVE HUMIDITY
Range 25% to 95%
Resolution 1%
Memory Minimum / maximum
WEATHER FORECAST
Display Rainy, cloudy, partly
cloudy, sunny
REMOTE SENSOR (THGR122NX)
RF frequency 433 MHz
Range 30 metres (98 feet) with
no obstructions
Transmission every 40 seconds
Channel No. 1-3
CLOCK
RF Clock Auto or manual (disabled)
Clock display HH:MM:SS
Hour format 12hr AM / PM
(Model BAR628HGU)
24hr (Model BAR628HG)
Calendar DD / MM; weekday in
5 languages (E, D, F, I, S)