Saunatec IG-540-BH-2 5/25/07 Marine Sanitation System User Manual


 
IG-540-BH-2 5/25/07
7. Place the top panel on the four side panels. Make sure the connection wires from the three side
panels protrude through the corresponding holes of the top panel.
Make sure the top panel’s arched side is facing to the front.
Make sure the wire is through each hole smoothly and completely.
Make sure trim of the top panel fits completely around the four side panels.
8. Make sure each of the lead wires on the top of the left, right, back and front panels is
protruding through the top panel; then plug each of the four lead wires into the four
connectors of the top panel.
WARNING: ELECTRIC SHOCK HAZARD
Do not plug cord into electrical outlet before connecting power cord wires to terminal block.
9. Make sure to connect wires in correct location by matching color to correct screw location:
Open cover on top side of ceiling panel to see three unconnected power wires (Picture 1)
Insert the green wire into ” and tighten the screw (Picture 2)
Insert the black wire into “L” and tighten the screw (Picture 3)
Insert the white wire into “N” and tighten the screw (Picture 4)
Visually inspect to ensure the correct connections by color (Picture 5)