Schumacher PI-140 Marine Battery User Manual


 
• 6 •
7. IF THE INVERTER FUSE BLOWS
Your power inverter is tted with a fuse, which should not have to be replaced
under normal operating conditions. A blown fuse is usually caused by reverse
polarity or a short circuit within the device or equipment being operated.
If the fuse does blow:
1. Disconnect the device or equipment immediately.
2. Find the source of the problem and repair it.
3. Install a new fuse (15A). The fuse can be found on the end of the plug on the
inverter.
4. Do not tighten the fuse cap too tight; nger-tight is sufcient.
ATTENTION: Do not install a fuse higher than 15A, as this may damage
the inverter. Make sure to correct the cause of the blown fuse before using the
inverter again.
8. TROUBLESHOOTING
PROBLEM REASON SOLUTION
LEDs do not light,
or inverter does not
function.
Poor contact at
terminals.
Fuse blown.
Inverter shutdown.
Inverter may not be
working properly.
Unplug and reinsert the 12 volt
plug.
See “IF THE INVERTER FUSE
BLOWS” section.
See “LED INDICATOR AND
SHUTDOWN PROTECTION”
section.
See Warranty and call Customer
Service.