• 15 •
PROBLEM REASON SOLUTION
Inverter does not turn on. Poor contact at terminals
Fuse is blown.
Inverter may be defective.
Check for poor connection
to battery or power supply.
Make sure connection points
are clean. Rock clamps
back and forth for a better
connection.
A blown fuse is usually
caused by reverse polarity
or a short circuit within the
inverter.
To replace, contact a qualied
service technician who will
diagnose the inverter and
replace the fuse(s) with the
appropriate replacement(s).
See warranty and call
Customer Service 1-800-621-
5485 (Hours 7:00 am to 5:00
pm CST).
SPECIFICATIONS10.
Model: PID-410 / PIF-410
Maximum Continuous Power 410 Watts
Surge Capability (Peak Power) 820 Watts
No Load Current Draw <0.4A
Wave Form Modied Sine Wave
Input Voltage Range 10.5V – 15.5V DC
Output Voltage Range 120V ± 5% AC
Low Battery Alarm Audible, 11V ± 0.3V DC
Low Battery Shutdown 10.5V ± 0.3V DC
High Battery Shutdown 15.0V ± 0.5V DC
Optimum Efciency 85%
AC Outlet Two, NEMA 5 - 15 USA
DC Output One, USB 5V 0.5 Amp
Dimensions 5” L x 4” W x 2.2” H