Seagate FR-A7AY Marine Battery User Manual


 
22
DIGITAL OUTPUT
5.2 Terminals
By setting the Pr. 313 to Pr. 319 values, output signals available with an inverter as standard can be output
from the open collector terminals.
(1) Open collector output specifications: Permissible load 24V, 0.1ADC
(2) The circuit logic is the same as that of the inverter.
For details of changing the control logic, refer to the inverter manual (basic).
Terminal Symbol Terminal Name Description
Y0
Digital output
terminals
Use Pr. 313 to assign functions.
Y1 Use Pr. 314 to assign functions.
Y2 Use Pr. 315 to assign functions.
Y3 Use Pr. 316 to assign functions.
Y4 Use Pr. 317 to assign functions.
Y5 Use Pr. 318 to assign functions.
Y6 Use Pr. 319 to assign functions.
SE
Common
terminal
This is a common terminal (for sink and
source).
AM0
Used for analog output function. (Refer to page 11) AM1
AMC
NC (empty) Do not use.
NC
NC
AMC
SE
Y3
Y4
Y5
Y6
AM0
AM1
SE
Y0
Y1
Y2