15
4. See if the PFD will float you on your back or just slightly
back of vertical. In a relaxed floating position, verify that
your mouth is well above the water's surface. Note the
effect of where you hold your legs on how you float.
5. Get out of the water and remove the PFD. Remove the
used CO
2
cylinder and the used pill from the PFD inflator.
Deflate the PFD using the oral inflator.
6. Let the PFD dry thoroughly. REARM and REPACK the PFD
in accordance with the manufacturer’s instructions!
HOW DO YOU TEST YOUR PFD USING THE MANUAL
INFLATOR?
1. To test your inflatable PFD, you will need:
• Your fully armed PFD, and
• Rearming kit approved for your PFD. (This kit
contains a water sensing pill that you will need to use
following this test.)
2. Put on the PFD.
3. Actuate the inflation system by jerking firmly downward on
the pull tab. The PFD should fully inflate within 5 seconds.