7
Troubleshooting
Try these remedies for common Inverter problems before calling for assistance. Visit www.tripplite.com/support before returning your unit for service.
SYMPTOM PROBLEMS CORRECTIONS
No AC Output
(All Indicator Lights Are OFF)
Operating Mode Switch is set to “OFF.” Set Operating Mode Switch to “REMOTE” or “ON.”
User-supplied UL-listed external DC input fuses
have blown. Replace fuses.
Replace fuses
Red Battery Indicator Light
Is Rapidly Flashing
(¼ Second Flashes)
Unit has shut down due to excessive
battery discharge.
Run your engine to raise battery voltage. Check external
battery connections and fuse. Reset by moving Operating
Mode Switch to “OFF.” Wait one minute and switch to
“REMOTE” or “ON.”
If unit remains in shutdown mode after several attempts to
reset contact Tripp Lite Customer Service for assistance.
Red Load Indicator Light
Is Rapidly Flashing
(¼ Second Flashes)
Unit has shut down due to overload. Reduce load. Reset by moving Operating Mode Switch to
“OFF.”
Wait one minute and switch to “REMOTE” or “ON.” If unit
remains in shutdown mode after several attempts to reset
contact Tripp Lite Customer Service for assistance.
Connected Equipment Experiences Audio/Video interference. Reposition equipment antennas and Inverter.
Inverter Output Seems Intermittent Loose cable connections. Check and secure all connections.
Service
Your Tripp Lite product is covered by the warranty described in this manual. A variety of Extended Warranty and On-Site Service Programs are also
available from Tripp Lite. For more information on service, visit www.tripplite.com/support. Before returning your product for service, follow these
steps:
1. Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of the
instructions.
2. If the problem continues, do not contact or return the product to the dealer. Instead, visit www.tripplite.com/support.
3. If the problem requires service, visit www.tripplite.com/support and click the Product Returns link. From here you can request a Returned Material
Authorization (RMA) number, which is required for service. This simple on-line form will ask for your unit’s model and serial numbers, along with
other general purchaser information. The RMA number, along with shipping instructions will be emailed to you. Any damages (direct, indirect,
special or consequential) to the product incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under
warranty. Products shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid. Mark the RMA number
on the outside of the package. If the product is within its warranty period, enclose a copy of your sales receipt. Return the product for service using an
insured carrier to the address given to you when you request the RMA.
Maintenance
Your Inverter requires no maintenance and contains no user-serviceable or replaceable parts, but should be kept dry at all times. Periodically check, clean
and tighten all cable connections, as necessary, both at the unit and at the battery.
GROUND
HI
MED
LOW
LOW
MED
HI
REMOTE
REMOTE
OFF
ON
LOAD
SENSE
GREATER
LOAD
ON
LESSER
LOAD
ON
BATTERY
LOAD
20A
15A
15A
20A
OUTPUT
CIRCUIT
BREAKER
20A
OUTPUT
CIRCUIT
BREAKER
20A
Operating Mode Switch
Battery Indicator Lights
Load Indicator Lights