Uniden MC2700 Marine Radio User Manual


 
_h_- -.--
_. ---
OPERATING PROCEDURE TO TRANSMIT
CAUTION
The transmitter Voltage Standing Wave Ratio (V.S.W.R.) measurement must
be performed prior to the use of the transmitter. A V.S.W.R. ratio in excess
of 2:1 may damage the transmitter.
1. Be sure the operator has read and understands DOTAC Rules and Regulations prior to
operating the transmitter.
2. Select the desired channel.
3. If the channel is clear, depress the push-to~talk switch on the microphone and
speak in a normal voice.
OPERATOR TROUBLESHOOTING
Should the unit malfunction or not perform properly, the operator should perform
the procedures indicated below:
1. If the transceiver is completely inoperative.
* Check the power cord and fuse.
2. If trouble is experienced with receiving.
* Check
ON/OFFVOLUMECONTROLsetting.
* Besure SQUELCH is adjusted properly. Isthe radio over-squelched?
* Checkto seethat the radio isswitchedto an operational mode.
3. If trouble is experienced with transmitting.
* Check to see that the transmission line (coaxial cable) is securely connected to
the ANTENNA CONNECTOR.
* Be sure that the antenna is fully extended for proper operation.
* Be sure that all transmission line (coaxial cable) connections are secure and free
of corrosion.
-3-
'9::
--
I
1 ,
-----